Produse pentru testează (169)

Tester Universal de Tracțiune - Tester Universal de Compresie și Îndoire

Tester Universal de Tracțiune - Tester Universal de Compresie și Îndoire

The universal tensile tester is used for performing tension, pressure or bending tests. The classic application is the tensile test. This involves subjecting a sample to an increasing tensile load until it breaks. According to ISO 527 , ISO 6259 , ASTM D 638 , servo controlled , long travel extensometer , ball screw , double column , USB computer controlled , windows based software • - Easy operation and clear visualization (test curves, calculations) via integrated touch display 16″ • - Easy to change the grips via male-female connection • - Accuracy: ±0.5% of full scale • - Precise, self-cleaning ball-screw • - Brush-less servo motor quarantine maintenance-free operation • - Easy calibration of load-cell • - Socket connection of extensometer as standard option Data export :Microsoft Excel Data port :USB Main motor :AC servo Screws:Ball screw Mechanical transmission :Belt and pulley Accuracy :0.5% Extensometer :Option Test force :Customer request Crosshead speed :up to 300mm/min Manual up/down :included
Tester de conținut de gel ASTM D 570 - Tester de conținut de gel pentru țevi și fitinguri PEX

Tester de conținut de gel ASTM D 570 - Tester de conținut de gel pentru țevi și fitinguri PEX

Test samples of PEX need to be immersed in boiling solvent and the insoluble part measured. The percentage of this part is degree of crosslinking. For this, we recommend a laboratory assembly consisting of a round glass fl ask with a heating jacket, a Dimroth cooler, a ring stand with suitable clamps and test holders with lids for the sample. To complete the measurement you will also require a heating oven and analytical balance. According to ISO 10147 , DIN 16892 , ASTM D 2765
Cine efectuează teste EMC - Ce organizații efectuează teste EMC

Cine efectuează teste EMC - Ce organizații efectuează teste EMC

EMC Testini Kimler Yaptırır Tüm elektrik ve elektronik ile ilgilenenler tarafından yaptırılmaktadır. Günümüzde çoğunlukla karşımıza çıkmaktadır.Otomotiv sanayi vb. Elektrikli ve ekeltronik cihazların imalatçı ve ithalatçı olarak, ürünlerinizin diğer elektrikli cihazlarla uyumlu olduğundan emin olmanız önemlidir. Uyumluluğu temin etmek için, yönetimler EMC standartlarını uygulamaya koymuşlardır. Pille çalışanlardan yüksek voltajlı kurulumlara kadar her yerde , elektrikli cihaz ve sistemlerin tümü için kuralları olup belirlemektedir. Herkezin kendi adına EMC kriterlerine sahip ürünlerinde bazı beklentileri vardır. Elaktromanyetik Uyumluluk (EMC) Direktifi - 2004/108/EC elektrikli ve elektronik cihazların, diğer cihazları etkilememesi için sadece sınırlı miktarda RF paraziti yaratmasını gerektirmektedir.
Analizor de dispersie a negru de carbon - Analizor de dispersie a negru de carbon pentru poliolefine

Analizor de dispersie a negru de carbon - Analizor de dispersie a negru de carbon pentru poliolefine

A microscope is required to examine the agglomerates in polyelefins for determining the degree of dispersion. The digital camera is used for images acquisition, documentation and archiving. It is supplied with image processing software and a PC for automatic determining the dispersion grade. According to ISO 18553 , ASTM D 5596
EP60 - Standarde IP

EP60 - Standarde IP

Elektronik komponentlerin toza, kire ve buhara maruz kalmasının ürünler üzerinde negatif etkilere sebep olur. Bu negatif etkiler paslanma, kısa devre ya da performans sorunları şeklinde kendini gösterebilir. Bu sonuçların önüne geçebilmek için elektronik ürünlerin sızdırmazlık testleri yapılmalıdır. Elektronik ürünlerin ve iç hacmin basınçlandırılmasının mümkün olmadığı uygulamalarda basınç düşümü yöntemini kullanarak sızdırmazlık testinin yapılması için ürünün dış hacmi basınçlandırılmalıdır. EP60- IP standartları sızdırmazlık test aparatı kullanılarak IP67, IP68 ve hermetik özellik testleri yapılabilir. BT4000 Serisi cihazlarla birlikte çalışan ürün hızlı, raporlanabilir ve hassastır. - Suya daldırma metodundaki belirsizliklerden, ıskarta ürün maliyetinden kurtulun. - İstenilen formatta oluşturulan test raporları IoT kullanılarak uzaktan takip edilebilir, USB bellek ile bilgisayara taşınabilir ve Excel formatında incelenebilir."
Mașină de frezare a crestăturilor pentru testul SCG ISO 13479 - Mașină de frezare a crestăturilor pentru testul SCG al țevilor HDPE

Mașină de frezare a crestăturilor pentru testul SCG ISO 13479 - Mașină de frezare a crestăturilor pentru testul SCG al țevilor HDPE

It is used for making V-shaped nothes in polyolefin pipes in accordance with ISO 13479 for slow crack growth testing. Digital notch depth monitor, digital notch length control, motorized sample holder, speed adjust
Care sunt standardele LVD - Care sunt standardele de testare LVD?

Care sunt standardele LVD - Care sunt standardele de testare LVD?

Standardizasyon AB Tek Pazar oluşturma konusunda öncü bir rol oynamıştır. Standartlar piyasa temelli rekabeti destekleyen ve tamamlayıcı ürün ve hizmetlerin birlikte çalışabilirliği sağlamak açısından yardımcı olur. Onlar, maliyetleri azaltmak güvenliğini artırmak ve rekabeti geliştirmek için savaşırlar ve mücadele ederler . sağlık, emniyet, güvenlik ve çevrenin korunması rolleri nedeniyle standartlar kamuoyunda önemlidir. AB, Avrupa sanayisinin rekabet gücünü daha iyi düzenlemeler için bir yol olarak standartları teşvik ve geliştirmek aktif standardizasyon politikası vardır. Yani kısacası standartlar rekabetin artması için çıkarılmıştır. AB'de standardizasyon politikası Evrimi Standardizasyon Ortak Girişimi Standardizasyon Ortak Girişimi konu başlığı altında öngörülen, Tek Pazar Stratejisi , açık kamu-özel işbirliği yoluyla önceliklere ulaşmanın yenilikçi bir çıkış yolu olarak belirlenir.
Teste fără halogeni - HFFR retardant de flacără fără halogeni

Teste fără halogeni - HFFR retardant de flacără fără halogeni

HFFR (Halogen Free Flame Retardant – Halojensiz Alev Geciktirici) malzemeler esas olarak Etilen Vinil Asetat (EVA), Alüminyum Tri Hidroksit (ATH) ve Polietilen (PE) içeren kampaundlardır. Bazı ürünlerde alev geciktirici olarak ATH yerine Magnezyum Oksit kullanılsa da bu ürünler genelde çok pahalı olduğu için Türk malzeme üreticileri tarafından pek tercih edilmez. Halojensiz alev iletmeyen özellikle şirket binaları, hastaneler, alışveriş merkezleri, oteller, sinemalar, yeraltı metro, elektrik santralleri, yangınla ilgili merkezler gibi insanların toplandığı yerlerde yangın esnasında insan hayatının, değerli malzemelerin ve önemli belgelerin korunması için geliştirilmiştir. Yangın esnasında bu binalardaki yangın alarm sistemleri, havalandırma sistemleri, asansörler, ikaz ve yönlendirme ışıkları, kapılar en azından bir süre çalışır olmalıdır. Bundan dolayı bu sistemlerin besleme ve kontrol kabloları halojensiz (HFFR), emniyet kabloları olmalıdır.
Unitate de Testare a Presiunii Hidrostatice ISO 1167 ASTM 1598 - ASTM D 1598

Unitate de Testare a Presiunii Hidrostatice ISO 1167 ASTM 1598 - ASTM D 1598

maximum accuracy, a long service life and a userfriendly system, combined with flexibility Highprecision pressure regulation, selectively regulated input pressure in each Line All metal components that come in contact with the medium is brass ans SS304 Quick system calibration easily by the operator and calibration data saved in the controller modules Convenient operation, evaluation of results and clear visualization via Labview and windows based software Operator access to all important settings from the front panel Each station can be individually isolated from the supply pressure for service purposes PLC based control of the pressure channels Pressure gauge for checking each line actual pressure
Analize de Testare a Tensiunii Mici LVD - Laboratoare de Testare a Tensiunii Mici LVD

Analize de Testare a Tensiunii Mici LVD - Laboratoare de Testare a Tensiunii Mici LVD

2006/95 EEC Alçak Gerilim Direktifi (LVD) kapsamında toprak hattı süreklilik testleri akredite laboratuvar, kalibre edilmiş cihazlarımız ve uzman personelimiz tarafından profesyonel şekilde gerçekleştirilir. Toprak hattı sürekliliği için gerekli olan tüm teçhizat bünyemizde mevcuttur. Testler toprak üzerindeki akımı ölçmek için yapılır Toprak hattı sürekliliği ölçümü için mevcut toprağın özdirencinin tespiti zorunludur. aşağıdaki değerler tablosu incelenebilir ; LVD Yönetmeliği kapsamındaki elektrikli teçhizatın örneğin ; Metal işleme makineleri Plastik ve Lastik Makineleri Ağaç işleme makineleri, Kaldırma makineleri ,Gıda makineleri ,Kağıt ve karton makineleri, Baskı Makineleri,Montaj makineleri,Tekstil makineleri, medikal cihazlar, aydınlatma cihazları, elektrik motorları gibi cihazların bu Yönetmelikte belirtilen emniyet gerekleri ve uygunluk değerlendirme prosedürlerini sağladıktan sonra, piyasaya arzı için ilgili emniyet kuralları ile uygunluk değerlendirmesidir.
Incubator cu sistem de răcire

Incubator cu sistem de răcire

Digital controller
Laboratoare de Testare LVD - Laboratoare care Efectuează Teste LVD

Laboratoare de Testare LVD - Laboratoare care Efectuează Teste LVD

Eurolab ilk önce standartların evrimi bilmesini sağlar Avrupa düzeyinde bir teknik komite bir parçası olması ve daha sonra müşterilerine yeni düzenleyici gereksinimleri rapor verir. Eurolab azından Avrupa ve Uluslararası elde etmek için sertifikasyon testleri ve tamamlama uygulamaları çalıştırabilir Sertifikalar. Eurolab Rohs Direktifi gelişiyle Direktifin gereklerini yürütmek için teçhizat ve eğitim yatırım yapmıştır. Sen aslında tamsayılar homojen malzeme veya ürünlerin kendi laboratuar XRF kontrolleri gerçekleştirebilirsiniz ve son olarak dosya Uyum oluşturulmasına. Laboratuvarda bir iç bölümü, çalışma ve müşteri ihtiyaçlarına göre özel test cihazları uygulamak mümkün zorunlu düzenlemelerin gerektirdiği normal testleri ötesinde. Stres testleri, dayanıklılık, yaşlanma döngüleri, güvenilirlik doğrulama, araştırma guatsi, ve diğerleri ..
Înfășurare de fir CNC pentru fitinguri de electrofuziune

Înfășurare de fir CNC pentru fitinguri de electrofuziune

CNC wire winding for electrofusion fittings insert wire winding
Tester de Conținut de Carbon - Tester de Conținut de Carbon pentru materiale plastice

Tester de Conținut de Carbon - Tester de Conținut de Carbon pentru materiale plastice

The test method is based on pyrolitic decomposition of the material in an inert gas flow (nitrogen). According to ISO 6964 , ASTM D 1603 , maximum temp 1000C, quarts tube, rotameter for N2 gas flow adjustment, sliding sample carrier, alumina sample boat, digital temperature and time control, glass ware and chemicals according to the standard including trap, u tube, silicagel pellets, pyrogallol solution
Cameră de testare a inflamabilității

Cameră de testare a inflamabilității

The Horizontal Vertical Flame Chamber provides the most accurate means for determining the flammability of aircraft cabin and cargo compartment materials, liners and waste stowage compartment materials, and electric wire. Three digital timers make specimen event timing precise and convenient. The series of horizontal-vertical flame test apparatus are designed and manufactured according to the standard and related requirement of UL94 , IEC60695-11-2 , IEC60695-11-3 , IEC60695-11-4 , IEC60695-11-20. It simulates the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. It is mainly used in plastic and other non-metallic material sample, solid material. It is also applicable in the Horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is no-less than 250kg/m according to ISO845 test method.
Teste pentru Acoperișuri și Materiale Compuse - Laborator de Testare a Acoperișurilor și Materialelor Compuse

Teste pentru Acoperișuri și Materiale Compuse - Laborator de Testare a Acoperișurilor și Materialelor Compuse

Endüstriyel hafif çelik yapılar için mekanik bağlantı elemanı teknolojisi ileüretilen çatıların, Tek ve Çift Yüzeyli Konstrüksiyonlar, Kenet Çatı Sistemi, Kompozit Panel, Oluklu Elyaflı Çimento Paneli, Çatı ve Cephe, Bağlantı Teknolojilerinin tüm standardlara uygunlu test ve muayenelerini gerçekleştirmekteyiz. Montaj araçları doğru sabitlemeyi sağlamlaştırmak ve performansı arttırmak için geliştirilen tüm ürünlerin de test ve analizlerinide gerçekleştimekteyiz. Formlandırılmış alüminyum kompozit panel kaplamalarının alt taşıyıcı strüktürler, Korozyona, ani basınç değişikliklerine ve rüzgar yüküne karşı dayanıklı bir dış cephe giydirmeler, Üzerine uygulanan kaplamalar ile korozyon ve iç bölmelere nemin geçişler, Duvarla kompozit panel arasına uygulanan ısı yalıtım üniteleri ile (ekstürüde polistiren, cam yünü veya taş yünü) ısı yalıtımlerı, Alüminyum kompozit paneller dış cephe kaplamalarında kullanılabildiği gibi bazı iç yüzey kaplamalarıdır.
Etanșeitate sub îndoire EN 921

Etanșeitate sub îndoire EN 921

This unit is used for performing leak tests on mechanical joints between fittings and pressure pipes under hydrostatic internal pressure while subjected to bending.
Cuptor cu aer cald

Cuptor cu aer cald

The forced air oven is used to condition samples for tests such as longitudinal reversion and as a drying oven (e.g. for water absorption, etc.). According to ISO 2505