Produse pentru twisture (6)

Conductor neizolat cu fire de aluminiu răsucite - NEIZOLAT

Conductor neizolat cu fire de aluminiu răsucite - NEIZOLAT

For transmission of electric power in overhead electric networks, used in I and II type atmospheric air provided that the content of sulphur trioxide in the atmosphere is not more than150mg/m2 per day (150mg/m3) and according to standard 15150-69 in all microclimatic regions of the land.The conductor is made of aluminum wire by twisting. In case of twisting in layers, the twisting is performed in opposite directions. Indicated in the table. According with customer’s request and agreement conductors with different construction length can be manufactured. STANDARD:GOST 839-2019 FOREIGN ANALOGUE:А GOST 839-80 | AAC IEC61089,SFS 5701
Conductor flexibil neizolat, răsucit din fire de cupru - NEIZOLAT

Conductor flexibil neizolat, răsucit din fire de cupru - NEIZOLAT

In electric equipment and devices, as well as in electric system of railway.The conductor is made from copper multi-core wire by twisting, class IV flexibility according to standard GOST 22483-2012. Nominal section of the conductor is 1.5-up to 150mm2.according to the sections it is as follows: 1,5 : 6mm2 inclusive 50m 10 : 25mm2 inclusive 2000m 35 : 70mm2 inclusive 1000m 95 : 150mm2 inclusive 500m By the request and agreement with the customer conductors with different construction length can be manufactured. STANDARD:GOST 26437-85 T.C 16.705466-87 FOREIGN ANALOGUE:МГ Гост 26437-85 | ТУ 16.705466-87
Conductor neizolat, răsucit cu fire de cupru - NEIZOLAT

Conductor neizolat, răsucit cu fire de cupru - NEIZOLAT

For transmission of electric power in overhead electric networks, used in I and II type atmospheric air provided on land and sea in all microclimatic regions of the land according to standard 15150.The conductor is made from copper wire by twisting. In case of twisting in layers, the twisting is performed in opposite directions. Half side of the outer layers is right direction.indicated in the table. By request and agreement with the customer conductors with different construction length can be manufactured STANDARD:GOST 839-2019 FOREIGN ANALOGUE:М GOST 839-2019
Conductori din oțel-cupru răsuciți neizolați - NEIZOLAT

Conductori din oțel-cupru răsuciți neizolați - NEIZOLAT

For power supply of railway system, including contact systems. Conductor is defined in all macro-climatic areas I, I I, I, IV type of atmosphere standard according to the standard 15150The conductor is twisted from galvanized steel and copper wires not less than 1600m. By request and agreement with the customer conductors of different construction length can be manufactured. STANDARD:GOST 4775-91 MS 15716715-001-2010 FOREIGN ANALOGUE:GOST 4775-91
Cablu (sfoară) răsucit cu fire de oțel - NEIZOLAT

Cablu (sfoară) răsucit cu fire de oțel - NEIZOLAT

In coal mining, gas-and-oil producing industry, metallurgy, engineering, construction industry, sea and river transport. It can be used as lightning protection at high voltage lines.Steel cable (rope) is made of galvanized steel wire (number of wires 19) twisted as single or in layers and is covered with anticorrosive temperature resistant lubricant material. agreed with the customer. Deviation from length is possible: up to 400m +5%, above 400m +20%. STANDARD:GOST 3241-91, 3063-90 FOREIGN ANALOGUE:С GOST 3241-91 | 3063-90
Conductor neizolat cu miez din oțel și fire de aluminiu - NEIZOLAT

Conductor neizolat cu miez din oțel și fire de aluminiu - NEIZOLAT

AS: For transmission of electric power in overhead electric networks, used in I and II type atmospheric air provided that the content of sulphur trioxide in the atmosphere is not more than150mg/m2 per day (1.5mg/m3) and in all microclimatic regions of the land according to standard 15150-69. ASKP and ASKS: Used on the seashores, in industrial regions, salty sandy regions, as well as regions adjoining them in II and III type atmospheric air provided that the content of sulphur trioxide in the atmosphere is not more than150mg/m2 per day (1.5mg/m3) and Chlorine salt not more 200 mg/m2 ,in all microclimatic regions of the land according to standard 15150.The conductor is made by twisting of the steel conductor and aluminum wire. Regarding to the structure, the steel core is single-wire or twisted multi-wire. In case of twisting in layers, the twisting is performed in opposite directions. STANDARD:GOST 839-80 FOREIGN ANALOGUE:АС GOST 839-80 | ACSR IEC 61089