Produse pentru testează (7)

Curs de Formare Software Dianel-pro "Metoda de Testare a Sănătății Nonlineară"

Curs de Formare Software Dianel-pro "Metoda de Testare a Sănătății Nonlineară"

Attention! Training of 1 person is included in the price of equipment for retail customers. Training of more persons is charged at the established training prices. Syllabus of the training seminar «New techniques of examinations with the help of hardwaresoftware systems for nonlinear bioresonant diagnostics «DIANEL» and «DIANELPRO» software The courses are held internally in the office CIT Nelian, or online by Skype with video and images and broadcast video sharing. Training is conducted individually at the agreed time with the customer. Furthermore, in accordance with the desire of the Student, a cultural program can be offered (to be coordinated beforehand) Excursion across Moscow; Visiting Museums Theatres Exhibitions
Sisteme de magneți permanenți pentru testarea dispozitivelor medicale

Sisteme de magneți permanenți pentru testarea dispozitivelor medicale

For testing cardio-stimulators and other medical devices, a set of the magnetic field sources was designed having a magnetic flux density in the working area from 1 to 300 mT. Values of the magnetic field in the working area:1, 10, 50, 100, 200, 300 mT Magnetic system material:NdFeB The inter-pole gap:25 mm Dimensions of the working:Area ø 150 x 20 mm The field inhomogeneity in the working area:~ 1 % Overall system dimensions:180×260×260 mm
Stand de teste hidraulice - Test de cap de cilindru

Stand de teste hidraulice - Test de cap de cilindru

The СГИ 1200 cylinder head test stand is designed to detect micro cracks and air-tightness of the engine cylinder heads. The stand is equipped with a turntable for rotating the cylinder head in an aqueous solution and detecting tightness defects in different planes. This is a professional stand with pneumatic lifting and lowering of the turntable and electric 360-degree platform rotation drive. The cylinder head is sealed and placed in a heated aqueous solution. Thermal expansion of a heated part allows you to detect microcracks between valve seats, damaged plugs and other places in the cylinder head. Air is supplied through the opening in the cylinder head at a pressure of 4-6 bars. The presence of air bubbles allows you to detect a defective spot in the head. Washing space length:Min 800 mm, Max 1600 mm Washing space width:Min 260 mm, Max 400 mm Washing space height:Min 280 mm, Max 400 mm Capacity (maximum):350 kg/ sq.m.
Mașină hardware-software Dianel-5120 pentru răspuns galvantic al pielii pe 2 canale

Mașină hardware-software Dianel-5120 pentru răspuns galvantic al pielii pe 2 canale

The Dianel5120 Hardware and software system with the professional «DianeliON» software can perform the objective psychophysiological condition assessment. Key features of Dianel5120 Hardware and software system Record of twochannel GSR signal Simultaneous recording of voice / sound (Dialog, talks between psychologist and patient). Collection of complaints and the patient's history with an option to register prior to the study. Conducting stress tests (active orthostatic test, samples with hyperventilation, breath holding test) with parallel GSR signal registration. Conduct psychological testing, using appropriate questionnaires and parallel registration signal GSR. Analysis and interpretation of the Galvanic Skin Response data eliminates the effects of perspiration (according to the method by Suhodoev V.V.); Selection and placing on health improvement products from a database program «DianeliON» according to the identified state.
Dianel®-Micro pentru diagnosticarea sănătății prin microscopie digitală

Dianel®-Micro pentru diagnosticarea sănătății prin microscopie digitală

Diagnostics by Hemaview with Digital Dark-field or Bright-field Microscope - Dianel®-Micro Microscopy Analysis Software for Health Hiagnostic with digital dark-field microscope or bright- field microscope supports the following Blood analysis methods: LBA (Live Blood Analysis, Hemaview) Dark-field blood microscopy according to Enderlein Blood analysis by Bradford system called HLB Dry blood analysis Oxidative stress levels and vitamin deficiencies (by Lagard and Heitan) Inflammations observable under the microscope Pleomorphism study by Bechamp microzymas Blood and tissues analysis by Dr. Prof. Gunther Enderlein concept of the pleomorphism of microorganisms Blood and tissues analysis by Dr. Prof. Gunther Enderlein hypotheses about the origins of cancer Classic medical Clinical Complete Blood Count research Research on diseases of saliva Assessment of the condition of the skin, nails and hair in cosmetology Free two-mounts trial available Free support and software updates
Sistem de Măsurare Automatizat pentru Testarea Parametrilor Magnetici

Sistem de Măsurare Automatizat pentru Testarea Parametrilor Magnetici

LLC "AMT&C" offers automatic measuring system (AMS) for measurements of the magnetocaloric effect and other magnetic parameters. AMS includes: - Halbach-type magnetic field source with changing magnetic field based on permanent NdFeB magnets, - liquid nitrogen cryostat, - the set of measuring inserts, - data acquisition and measurements control system guided by a control computer. AMS has the following working parameters: - variable magnetic field strength - from -1.85 to +1.85 T, - variable frequency of the magnetic field change from 0.1 to 1.8 Hz (magnetic field change rate from 0.05 to 6 T/s), - dimensions of the magnetic field area with heterogeneity no more than 1 % - diameter 20 mm, length 20 mm, - working temperature region – 80 ÷ 365 К, - automatic and manual measuring modes. The basic option of AMS is the magnetocaloric effect measurement. - sample dimensions (min-max) (1-2)×(2-5)×(8-10) mm, - measurement accuracy of magnetocaloric effect: 0.1 K.
Sistem de Câmp Magnetic pentru Testarea Non-distructivă a Dispozitivelor de Vid

Sistem de Câmp Magnetic pentru Testarea Non-distructivă a Dispozitivelor de Vid

This magnetic system is specially designed for non-destructive testing of pumped vacuum devices, that required the creation of a uniform magnetic field not only in the center of the operating bore, but in the toroidal region of large size. The system is assembled on the basis of NdFeB permanent magnets. Field direction:axial Field uniformity in a specified toroidal area:up to ±2% Magnetic flux density (for existing modifications):from 0.1 to 0.4 T Bore diameter:120 mm and more