Produse pentru releu led (10)

Releu PCB - OA 5661

Releu PCB - OA 5661

• According to DIN EN 61810-1, DIN EN 60664-1 • Different pin configurations and pin arrangements • Clearance and creepage distances: contact-coil ≥ 8 mm • Compact size, small height (horizontal model) • OA 5651, 5661 horizontal models • OA 5652, 5662, 5692 vertical models • Solder line proof Function:Printed circuit board relay Type of relay:monostabil Contact material:AgSnO2; AgNi Continuous current:8 A Nominal voltage UN DC:6 - 60 V Voltage Range UN:0,7 - 1,8 V Test voltage (AC) contact set - coil:≥ 4 kV eff Clearance and creepage distances, contact set - coil ≥:8 mm Temperature range (- / +):40 - 80 °C Protection type:RT II (flux-proof relay) Size L x W x H:28 x 25 x 10,8 mm Approvals:cRUus Relay type:OA 5661
Releu de timp

Releu de timp

Ein Zeitrelais ist eine spezielle Ausführung eines Relais, mit dessen Hilfe u. a. in der Steuerungs- und Automatisierungstechnik z. B. Ein- oder Ausschaltverzögerungen erreicht werden können. Das Produktspektrum bietet Zeitrelais mit Mehrfachfunktionen und einstellbaren Zeitbereichen sowie Relais mit speziellen Funktionen wie einschaltverzögert, ausschaltverzögert, taktgebend und Stern-Dreieck-Relais.
Releu PCB - OA 5682

Releu PCB - OA 5682

• According to DIN EN 61810-1, DIN EN 60664-1 • Clearance and creepage distances: contact-coil ≥ 8 mm • Compact size, small height (at horizontal model) • OA 5671 / 5681 horizontal mounting • OA 5672 / 5682 vertical mounting • OA 5671 and OA 5672 for continuous currents to 10 A or with contact with 5 μm Au • OA 5681 and OA 5682 for continuous currents to 16 A • OA 5672 as option with 7 mm or 10 mm pin distance • For continuous operating temperature to 110°C • Voltage range 0.7 UN ... 2.2 UN • Solder line proof Function:Printed circuit board relay Type of relay:monostabil Contact material:AgSnO2 Continuous current:16 A Nominal voltage UN DC:6 - 110 V Voltage Range UN:0,7 - 2,2 V Test voltage (AC) contact set - coil:≥ 4 kV eff Clearance and creepage distances, contact set - coil ≥:8 mm Temperature range (- / +):40 - 110 °C Protection type:RT II (flux-proof relay) Size L x W x H:29 x 12 x 25,5 mm Approvals:cRUus Relay type:OA 5682
Releu PCB - OA 5661.12

Releu PCB - OA 5661.12

• According to DIN EN 61810-1, DIN EN 60664-1 • Low rated power consumption • 2 changeover contacts • Clearance and creepage distances: contact - coil ≥ 8 mm • Adjustment to customers specification • Compact size, small height (at horizontal model) • OA 5661.12 horizontal mounting • OA 5662.12 vertical mounting • Solder line proof Function:Printed circuit board relay Type of relay:monostabil Contact material:AgSnO2; AgNi Continuous current:6 A Nominal voltage UN DC:6 - 60 V Voltage Range UN:0,7 - 1,4 V Test voltage (AC) contact set - coil:≥ 4 kV eff Clearance and creepage distances, contact set - coil ≥:8 mm Temperature range (- / +):40 - 70 °C Protection type:RT II (flux-proof relay) Size L x W x H:37 x 25 x 10,8 mm Approvals:cRUus Relay type:OA 5661.12
Releu miniatural - OR 5691

Releu miniatural - OR 5691

• According to DIN EN 61810-1, DIN EN 60664-1 • Clearance and creepage distances: contact - coil ≥ 5.5 mm • High dielectric strength ≥ 4 kV • High thermal continuous current Ith= 5 A • High switching power AC 250 V / 5 A • Compact size V = 2.47 cm3 • Very small volume DIL model, can be plugged into standard IC-socket • Wash proof RT III Function:Power miniature relay, Remanence Type of relay:Remanenz Contact material:AgSnO2; AgNi Continuous current:5 A Nominal voltage UN DC:4,5 - 48 V Voltage Range UN:0,8 - 1,3 V Test voltage (AC) contact set - coil:≥ 4 kV eff Clearance and creepage distances, contact set - coil ≥:5,5 mm Temperature range (- / +):40 - 65 °C Protection type:RT III (wash-tight) Size L x W x H:20,2 x 10,1 x 12,15 mm Approvals:cRUus Relay type:OR 5691
Releu bistabil - OB 5690

Releu bistabil - OB 5690

• According to DIN EN 61810-1, DIN EN 60664-1 • Safe separation according to IEC/EN 60730; IEC/EN 60335 • Poled • Clearance and creepage distances: contact - coil ≥ 8 mm • Low rated power consumption • High voltage resistance ≥ 4 kV • High mechanical service life • High continiuous thermal current • For pulse operation, continuous operation permitted • Large voltage range • Very low mutual capacitance • High switching power • Very small volume DIL model, can be plugged into standard IC-socket • Different connection arrangements and contact materials • Wash proof RT III Function:Power miniature relay Type of relay:bistabil Contact material:AgSnO2; AgNi Continuous current:5 A Nominal voltage UN DC:4,5 - 48 V Voltage Range UN:0,75 - 1,9 V Test voltage (AC) contact set - coil:≥ 4 kV eff Clearance and creepage distances, contact set - coil ≥:8 mm Temperature range (- / +):40 - 80 °C Protection type:RT III (wash-tight) Size L x W x H:20,2 x 10 x 16,5 mm Relay type:OB 5690
Releu de siguranță cu contacte ghidate forțat - OA 5621_D

Releu de siguranță cu contacte ghidate forțat - OA 5621_D

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • High switching safety because of gold plated double contacts • Clearance and creepage distances: contact - contact ≥ 5,5 mm • Low rated power consumption and holding power • High mechancial service life • High temperature range • High thermal continuous current • Voltage range 0.75 ... 1.2 UN • 15.5 mm height Function:Safety relays with double contacts Type of relay:monostabil Contact material:AgNi + 5 µm Au Continuous current:5 A Nominal voltage UN DC:6 - 110 V Voltage Range UN:0,75 - 1,2 V Test voltage (AC) contact set - coil:≥ 4 kV eff Clearance and creepage distances, contact set - coil ≥:5,5 mm Temperature range (- / +):40 - 80 °C Protection type:RT III (wash-tight) Size L x W x H:46,5 x 22 x 15,5 mm Approvals:TÜV; cRUus Relay type:OA 5621_D
Releu de siguranță cu contacte ghidate forțat - OA 5667/_____4

Releu de siguranță cu contacte ghidate forțat - OA 5667/_____4

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • Clearance and creepage distances: contact - coil ≥ 8 mm contact - contact ≥ 5,5 mm Double and reinforced insulation between contacts • Low rated power consumption • High voltage resistance ≥ 4 kV at contamination level 2 • High mechanical service life • Compact size, small height Function:Safety relays, reinforc. insulation Type of relay:monostabil Contact material:AgSnO2; AgNi Continuous current:6 A Nominal voltage UN DC:6 - 110 V Voltage Range UN:0,75 - 1,3 V Test voltage (AC) contact set - coil:≥ 4 kV eff Clearance and creepage distances, contact set - coil ≥:8 mm Temperature range (- / +):40 - 85 °C Type according to DIN EN 61810-3:A/B Protection type:RT II (flux-proof relay) Size L x W x H:27 x 25 x 10,8 mm Approvals:TÜV; cRUus Relay type:OA 5667/_____4
Releu de siguranță cu contacte ghidate forțat - OA 5669/3

Releu de siguranță cu contacte ghidate forțat - OA 5669/3

• According to DIN EN 61810-1, DIN EN 61810-3 • Clearance and creepage distances: contact - coil ≥ 8 mm, contact - contact ≥ 5.5 mm double and reinforced insulation between contact sets • Low rated power consumption • High mechanical service life • For high ambient temperature up to + 85°C • Compact size, small height • As option wash proof RT III Function:Safety relays Type of relay:monostabil Contact material:AgSnO2; AgNi Continuous current:5 A Nominal voltage UN DC:6 - 110 V Voltage Range UN:0,75 - 1,4 V Test voltage (AC) contact set - coil:≥ 4 kV eff Clearance and creepage distances, contact set - coil ≥:8 mm Temperature range (- / +):40 - 85 °C Type according to DIN EN 61810-3:A/B Protection type:optional RT III (wash-tight); RT II (flux-proof relay) Size L x W x H:29 x 13 x 25,5 mm Approvals:TÜV; cRUus Relay type:OA 5669/3___
Releu miniatural - OW 5699_SMD

Releu miniatural - OW 5699_SMD

• According to DIN EN 61810-1, DIN EN 60664-1 • Power miniature relay for SMD mounting • High switching power AC 250 V / 5 A • High dielectric strength 4 kV • High limiting continuous current Ith = 5 A • Compact size V = 2,47 cm3 • Safe separation L + K ≥ 5,5 mm EN 50178 Function:Power miniature relay, SMD Type of relay:monostabil Contact material:AgSnO2; AgNi Continuous current:5 A Nominal voltage UN DC:4,5 - 48 V Voltage Range UN:0,75 - 1,6 V Test voltage (AC) contact set - coil:≥ 4 kV eff Clearance and creepage distances, contact set - coil ≥:5,5 mm Temperature range (- / +):40 - 80 °C Protection type:RT III (wash-tight) Size L x W x H:20,2 x 10,1 x 13,5 mm Approvals:cRUus Relay type:OW 5699_SMD